Thank you for purchasing a Robertshaw RS5000 Series programmable
thermostat. This user’s manual will guide you through the setup of the
RS5110 single stage and the RS5220 two stage thermostats. The
thermostat should already be mounted and correctly wired. The default
settings will enable the thermostat to operate efficiently. Before making
any changes to the schedule read the section on Default Settings.
Features
Pop-Up Wizard
Automatic changeover
Circulating fan
Worry-Free memory retention
Easy change battery
Large back lit display
Filter change reminder
Low battery indicator
Fahrenheit and Celsius displays
EnergyStar™ compliant
Dual power
Adjustable 1
st
stage temperature differential: 0.5 F degrees to
3.0 F degrees (0.5 C degrees to 1.5 C degrees)
Accuracy within ±1 F degree
Universal staging on multi-stage units
Automatic heating shutdown if temperature exceeds 99°F (37°C)
Keypad security lockout
4 events per day for heating and cooling
5-2 day scheduling
User settable Hi and Lo temperature limits
Vacation setpoint override
1
RS4110
RS5110
RS
6
110
RS4220
RS5220
RS
6
220
352-00056-001
USERS MANUAL

Other manuals for Robertshaw RS4110

Questions and Answers

  • M
    mccormicktammyAug 12, 2025
    What to do if my Robertshaw RS4110 shows HI or LO but the room temperature is normal?
    • M
      Maria ReedAug 12, 2025
      If your Robertshaw Thermostat displays HI or LO while the room temperature is normal, it is recommended to call a licensed service person to replace the thermostat.
  • T
    Timothy HowellAug 16, 2025
    Why does my Robertshaw RS4110 Thermostat system turn on too often?
    • H
      Hector YoungAug 16, 2025
      If your Robertshaw Thermostat system turns on too often, increase the temperature differential. Refer to the Pop-Up Wizard section for guidance.
  • V
    Vickie GonzalezAug 20, 2025
    How to fix Robertshaw RS4110 Thermostat not displaying proper room temperature?
    • T
      Tina ReyesAug 20, 2025
      If your Robertshaw Thermostat is not displaying the correct room temperature, check the F/C (Fahrenheit/Celsius) setting. Please refer to the Pop-Up Wizard section for instructions.
  • B
    Brittany MooreAug 23, 2025
    How to fix a Robertshaw RS4110 Thermostat that does not turn on the system?
    • J
      James MillerAug 23, 2025
      If your Robertshaw Thermostat does not turn on the system, check the wiring. Refer to the Wiring Diagrams section for guidance.
  • K
    Kevin WallerAug 27, 2025
    What to do if Robertshaw Thermostat displays HI or LO with normal room temperature?
    • M
      Michael AlexanderAug 27, 2025
      If your Robertshaw Thermostat display shows HI or LO while the room temperature is normal, it's recommended to call a licensed service person for replacement or repair.
  • E
    edwardsdavidAug 31, 2025
    What to do if my Robertshaw Thermostat display shows HI or LO?
    • C
      Christopher HammondAug 31, 2025
      If your Robertshaw Thermostat displays 'HI' or 'LO' while the room temperature is normal, it indicates an issue that requires professional attention. It is recommended to call a licensed service person for replacement or repair.
  • J
    Jonathan HernandezSep 4, 2025
    What to do if Robertshaw Thermostat system fan does not operate properly?
    • E
      Ellen HallSep 4, 2025
      If the system fan on your Robertshaw Thermostat isn't working correctly, move the fan option switch to either gas or electric to match your system. See the System Switch Selection section for more details.
  • J
    John CollinsSep 7, 2025
    Why does my Robertshaw RS4110 Thermostat turn on too often?
    • H
      Hayley DoughertySep 7, 2025
      If your Robertshaw Thermostat is turning on too often, try increasing the temperature differential. This adjustment can be made within the settings.

Summary

Robertshaw Thermostat Key Features

Robertshaw Thermostat Application Overview

Thermostat Installation Safety Warnings

Thermostat Power Sources and Options

Thermostat Battery Replacement Guide

Thermostat Display Screen Layout Explained

How to Set Thermostat Time and Day

Default Thermostat Settings and Schedules

Understanding the Emergency Heat Function

Thermostat Auto Changeover Functionality

Changing Thermostat Programmed Settings

Editing Your Thermostat Schedule

Adjusting Thermostat Settings

Thermostat Security Lockout and Password

Thermostat Schedule Override Options

Permanent Thermostat Override

Switches to manual mode, displaying only the setpoint temperature for continuous operation.

Temporary Thermostat Override Guide

Sets a temporary setpoint for a specified number of hours, after which the schedule resumes.

Vacation Thermostat Override Setup

Sets a setpoint for a specified number of days, used for extended absences.

Determining Thermostat Setpoint Origin

Thermostat Automatic Shut-Down Feature Explained

Setting Thermostat Fan Mode

Robertshaw Thermostat Troubleshooting

Robertshaw Thermostat Warranty Information

Robertshaw RS4110 Specifications

General IconGeneral
TypeProgrammable
Stages1 Heat/1 Cool
Voltage24V AC
BacklightYes
Temperature Range45°F to 90°F
DisplayLCD
Featuresfilter change reminder