EasyManua.ls Logo

Robin DR400/120D - If the ALT Light Is Lit or the Ammeter Shows Battery Discharge During Normal Engine Operation for more than 5 Minutes

Robin DR400/120D
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supplement POH DR400/120D, DR400/140B,
DR400/180R, DR400/200R, DR400/RP
Page 3 - 18 Issue 3 July 2014
If the ALT“ light is lit or the ammeter shows battery discharge
during normal engine operation for more than 5 minutes
1) Alternator circuit breaker .................................................. Check ON
CAUTION: If the FADEC was supplied by battery only
until this point, the RPM can momentarily drop, when the
alternator will be switched on. In any case: leave the
alternator switched ON!
2) Check "ALT" light and voltmeter indications
3) If normal operation has not resumed:
Alternator ................................................................................... OFF
4) Switch OFF all electrical equipment not essential for continuation of
flight
5) Land as soon as possible

Table of Contents