5-5-2
FLEXIBLE COUPLING
When
a
flexible coupling
is
used,
the
runout and mis-alignment between
the
driven
shaft
and
the
engine driving shaft must
be
made
as
small
as
possible.
The
tolerances on
the
runout and mis-alignment
are
specified by
each
coupling maker.
5-6
WIRING
5-6-1
START
by
RECOIL
STARTER,
or
by ROPE
The
wiring
is
indicated in
the
wiring diagram given below. Normally,
the
portions indicated by
dotted
line
are
not wired in
the
engine
at
the
factory.
1)
Point system
MODEL
EY14
MODEL
EY18-3
~
Stoo Button
Lighting
Switch
Lamp
(6V-8V
\
'Ignition Coil
Lighting
Coil
(Optional Equipment, available
Spark Plug
Contact Breaker
la"
"-7
',15W)
if
required)
'
Lighting
Coil
(Optional Equipment, available if
MODEL EY25-2, EY27-2
,Condenser
required)
ir
.ed
)
Fig.
5-6-
7
-
15
-