Features 60W/100W output for charging up to 8 NiCd/NiMH cells or 4 Li-ion series.
Includes Delta-peak, capacity, temperature, and time limits for safe charging and discharging.
Covers unsupervised charging, environmental factors, surface placement, and connection safety.
Details voltage levels, charge currents, and cut-off points for various battery chemistries.
Emphasizes verifying capacity/voltage and avoiding deep discharge for Lithium batteries.
Stresses correct battery type selection and setting charge current/voltage for safe operation.
Sets charge current and voltage for Lithium batteries. Initiates process after confirmation.
Balances cell voltages during charging by monitoring and controlling current to each cell.
Sets discharge current and final voltage, preventing deep discharge and ensuring safety.
Details common errors such as polarity, connection, short circuits, voltage selection, and malfunctions.
Covers specific cell voltage, temperature, control, and connection errors for diagnosis.
| DC Input | 11-18V DC |
|---|---|
| Charge Current | 0.1-10.0A |
| Discharge Current | 0.1-5.0A |
| Charge Power | 100W |
| LiPo/LiFe/LiIon Cells | 1-6S |
| NiMH/NiCd Cells | 1-15S |
| Pb Voltage | 2-20V |
| AC Input | 100-240V AC |