8.2 Setup mode
In setup mode it is possible to check the basket drive operation and also to
change some parameters of the machine. To enter the setup mode, press
and keep pressed button #4, and then press ON/OFF button once. Once
St message appears on the display, release the button #4.
8.2.1 Basket operation check
Press and hold the button #3. Basket is being dumped while button is
kept pressed. Once the button released, basket returns back automatically.
8.2.2 Fine adjustment
Use ON/OFF button to list parameters. Use button #1 to decrease and
button #2 to increase the value. NOTE: all values are represented in dec-
imal format (ds or dd). For example, 150 ds is equal to 15 seconds.
Param Meaning Default value
A1 Basket return time, ds 0150
A2 Basket operation full cycle duration, ds 0300
A3 Time to drain-stop, ds 0030
A4 Drain-stop duration, ds 0070
P Proportional band, dd 0003
I Integral time, ds 0500
D Derivative time, ds 0100
H1 Temperature difference (oil level check), dd 0200
H2 Forced heating temperature difference, dd 0100
H3 Forced heating time, ds 0200
temp Oil temperature real time indication OFF
To reset all parameters to default values, press buttons #2 and #4
simultaneously, and then release them after 3 seconds (the display shows
DEF message).
18