Do you have a question about the Robopac ECOPLAT PLUS FRD USA and is the answer not in the manual?
Maximum Wrap Height | 87" |
---|---|
Machine Type | Semi-automatic stretch wrapper |
Power Consumption | 1.5 kW |
Film Width | 20" |
Film Pre-stretch | Up to 250% |
Power Supply | 120V |
Max Wrapping Width | 1200 mm |
Film Carriage Type | FRD - Film Reel Device (powered pre-stretch) |
General warnings emphasizing the importance of reading instructions and understanding risks.
Safety precautions for handling, loading, unloading, and installing the machine.
Safety warnings related to operating the machine, including training and PPE.
Covers foreseeable misuses and employer responsibilities for safe operation.
Details residual risks like slipping, impact, and shearing with corresponding safety measures.
Safety guidelines for performing machine adjustments and maintenance procedures.
Safety precautions related to the machine's electrical equipment and operating conditions.
Explains the position and meaning of safety and information signs affixed to the machine.
Details the step-by-step process of the machine's operation cycle, from loading to unloading.
Explains the function and location of various safety devices installed on the machine.
Guides the installation process, including positioning and lifting the machine using forklift forks.
Step-by-step guide for connecting the machine to the power supply, including checks.
Details how to adjust film stretch on the machine.
Details how to adjust film stretch using lever and handwheel for FRD type carriages.
Explains adjusting film stretch for mesh reels, focusing on outfeed and infeed roller braking.
Details the controls and functions available on the Ecoplat Plus Base model.
Details the controls and functions available on the Ecoplat Plus FRD model.
Guides on using the multi-function selector for cycle selection, parameter changes, and manual carriage movement.
Guides on starting and stopping the wrapping cycle, including manual and automatic modes.
Details the procedure for activating the emergency stop and restarting the machine after an incident.
Lists alarm messages, causes, and solutions for Ecoplat Plus and Ecoplat Plus FRD.