The sensor has set the default IP address to computer at factory, therefore, the default 
IP  address  of  the  computer  should  be  set  as  192.168.1.102,  sub-net  mask  as 
255.255.255.0. Besides, users should make sure that the RSView doesn’t be blocked by 
any firewall or third party security software. 
A.4 Visualization of Point Cloud 
1. Connect the RS-LiDAR-M1 to PC over Ethernet cables and power supply. 
2. Right click to start the RSView application with Run as Administrator. 
3. Click on the File -> Open -> Sensor Stream (Fig A-1). 
 
Fig A-1:Open the Sensor Stream in RSView. 
4. After finishing the above 3 steps, the dialogue box “Sensor Configuration” shows 
up.  In  this  dialogue  box,  the  Sensor  Calibration  default  contains  the  configuration 
folder named MEMSCorrectionFile_3V, select the corresponding file, click Add and then 
click the OK button (as shown in Fig A-2). The original point cloud data output from the 
RS-LiDAR-M1  is  already  calibrated  point  cloud  data,  therefore  the  value  in  this 
parameter file is void.   
 
Figure A-2:Select the parameter configuration file of RS-LiDAR- M1   
 
5. Check the MSOP and DIFOP port number: Tools > Sensor Network Configuration, 
choose ‘use udp’ and input the correct MSOP and DIFOP port number