Repair work
Installation
The installation takes place in the reverse
sequence. Please take note of the
following points:
Before installation, thoroughly clean and
grease the inside of the housing
When fitting the cap, make sure that the
cap spring [4A] is correctly fitted
Replace locking nut [3E] M5 DIN 98N
Install hand lever; Section 1.1
Check the coupling for correct
functioning; Section 2.1
LUBRICANTS
Multi-purpose grease
TIGHTENING TORQUES:
Bolt and nut [3A/E]
on cap ………….. 6 + 2 Nm
[4] A Cap spring