EasyManua.ls Logo

Rockwell Automation Allen-Bradley PowerFlex 4

Rockwell Automation Allen-Bradley PowerFlex 4
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-12 Programming and Parameters
Basic Program Group (continued)
P040 [Decel Time 1]
Related Parameter(s): P038, P039, A051, A052, A068
Sets the rate of deceleration for all speed decreases.
Values Default 10.0 Secs
Min/Max: 0.1/600.0 Secs
Display: 0.1 Secs
Maximum Freq
Decel Time
Decel Rate
=
Speed
0
Time
[Maximum Freq]
[Accel Time] [Decel Time]
0
Acceleration
De
c
e
lerat
ion
Stop drive before changing this parameter.
P041 [Reset To Defaults]
Resets all parameter values to factory defaults.
Options 0 Idle State (Default)
1 Reset Defaults After the reset function is complete, this parameter will set
itself back to 0.
Causes an F48 Params Defaulted fault.
userman.book Page 12 Friday, June 21, 2002 2:48 PM

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 4

Related product manuals