Programming and Parameters 3-15
Advanced Program Group (continued)
32 bit parameter.
A056 [Relay Out Level]
Related Parameter(s): A055
Sets the trip point for the digital output relay if the value of A055 [Relay Out Sel] is 6, 7 or 8.
Values Default 0.0
Min/Max: 0.0/9999
Display: 0.1 1
32
A055 Setting Min/Max
6
7
8
0/240 Hz
0/180%
0/815 Volts
A067 [Accel Time 2]
Related Parameter(s): P039
Sets the rate of acceleration for all speed increases except jog.
Values Default 20.0 Secs
Min/Max: 0.0/600.0 Secs
Display: 0.1 Secs
Maximum Freq
Accel Time
Accel Rate
=
Speed
0
Time
[Maximum Freq]
[Accel Time] [Decel Time]
0
Acceleration
De
c
e
lerat
ion
A068 [Decel Time 2]
Related Parameter(s): P040
Sets the rate of deceleration for all speed decreases except jog.
Values Default 20.0 Secs
Min/Max: 0.1/600.0 Secs
Display: 0.1 Secs
Maximum Freq
Decel Time
Decel Rate
=
Speed
0
Time
[Maximum Freq]
[Accel Time] [Decel Time]
0
Acceleration
De
c
e
lerat
ion
userman.book Page 15 Friday, June 21, 2002 2:48 PM

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 4 and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 4 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 4
CategoryDC Drives
LanguageEnglish

Related product manuals