13 Safety input and command status (TEST mode)
;MXLRSGYVVIRXP]EGXMZIGSQQERHWTVIWWXLI8)78FYXXSRERHGLIGOXLIJSPPS[MRK
DISPLAY POSSIBLE CAUSE ACTION BY SOFTWARE PHYSICAL CORRECTIVE ACTION
The safety STOP contact is open.
Incorrect setting of parameter .
Check that parameter is set cor
rectly
Install a STOP button (NC) or jumper the
ST contact with the COM contact.
Sensing edge COS not connected or
incorrectly connected.
238)ZMWMFPISRP]MJTEV is
Set the parameter if not used
or to disable.
Jumper contact ISEL with contact COM,
if not used or to disable
Photocell FT1 not connected or in
correctly connected.
Incorrect setting of parameter .
Set the parameter and
if not used or to disable.
Jumper contact FT1 with contact COM,
if not used or to disable. Check connec
tion referring to relative connection dia
KVEQƼKYVI
Photocell FT2 not connected or in
correctly connected.
Incorrect setting of parameter .
Set the parameter and
if not used or to disable.
Jumper contact FT2 with contact COM,
if not used or to disable. Check connec
tion referring to relative connection dia
KVEQƼKYVI
SS
If occurs with no voluntary com
mand, the contact (N.O.) may be
faulty or one of the buttons may be
incorrectly connected.
Check PP - COM contacts and connec
tions to buttons.
&+
Check CH - COM contacts and connec
tions to buttons.
DS
Check AP - COM contacts and connec
tions to buttons.
SH
Check PED - COM contacts and connec
tions to buttons.
2U
If occurs with no command, the
contact (N.O.) may be faulty or the
timer may be incorrectly connected.
238)ZMWMFPISRP]MJTEV is
Check ISEL - COM contacts. Contact
must not be jumpered if not used.
N.B: press TEST to exit TEST mode.
We recommend troubleshooting safety device and input status errors with “corrective action by software” only.