19
H70/200AC
ENC1
POWER
ALWAYS ON
FT1
COS1
COS2
FT2
FCA2
FCA1
FCC2
FCC1
AP
PP
CH
PED
ORO
ENC2
STOP
COMMAND STATUS SAFETY STATUS
FIGURE 2
PARAMETER
DISPLAY
FUNCTION
VALUE
DISPLAY
DESCRIPTION STANDARD
Leafs number
1 1 leaf
2
2 2 leafs
Automatic closing
0 not enabled
01-15 numbers of reclosing chances
99 it always reclosing
Pause time
0-90 pause seconds
30
92-99 2 minutes…9 minutes
Blackout emergency
0 it does not close after power-on
0
1 it closes after the power-on
closing delay leaf 1
0 not enabled
5
1-60 seconds delay
Preashing
0 not enabled
01-10 preashing seconds
99 5 seconds preashing only on closing
Step by step
0 open stop close stop
0
1 condominium, it renews pause
2
condominium,when it is completely open, it
closes
3 open close open close
4 open close stop open
Flashing light
0 xed
01 blinks every sec.
2 1Hz (opening), 2Hz (closing)
Limit switch
0 no limit switches
01 installed
2 only in opening
Standard torque 1-8 1= minimum torque, …., 8= max torque 6
Release thrust
0 not enabled
0
1-4 activation seconds
Encoder selection
0 not enabled
01 optical encoder
2 magnetic encoder
TABLE 2 “SIMPLE” MODE PARAMETERS
AP = open
CH = close
PP = step-by-step
ORO = timer input
FCA = limit switch open
FCC = limit switch close
FT = photocells
COS = safety edge
SAFETY NOT ENABLES:
corresponding LED
segment blinks
SAFETY ABSENT:
the segment is not shown
(e.g.: the 2 limit switches
status of motor 2 in case
You have only 1 leaf is
not showed)