EasyManua.ls Logo

Rohde & Schwarz R&S FSH Series - Page 17

Rohde & Schwarz R&S FSH Series
245 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data Sheet R&S
®
FSH3 and R&S
®
FSH6
1145.5973.12 TI.8 E-11
Measurement uncertainty 18 °C to 28 °C
same as for average power plus effect of peak hold
circuit
Error limits of peak hold
circuit for burst signals
Duty cycle 0.1 and
repetition rate 100/s
20/s repetition rate <
100/s
0.001 duty cycle < 0.1
Burst width 0.5 µs
Burst width 0.2 µs
video bandwidth 4 kHz
200 kHz
4 MHz
±(3 % of measured value + 0.05 W) starting from a
burst width of 100 µs
±(3 % of measured value + 0.20 W) starting from a
burst width of 4 µs
±(7 % of measured value + 0.40 W) starting from a
burst width of 1 µs
plus ±(1.6 % of measured value + 0.15 W)
plus ± 0.10 W
plus ± 5 % of measured value
plus ± 10 % of measured value
Range of typical measure-
ment error of peak hold
circuit for
cdmaOne, DAB
DVB-T, CDMA2000,
3GPP WCDMA
video bandwidth 4 MHz
and standard selected on
the R&S
®
FSH
±(5% of measured value + 0.4 W)
±(15% of measured value + 0.4 W)
Temperature coefficient
200 MHz to 300 MHz
300 MHz to 4 GHz
0.50 %/K (0.022 dB/K)
0.35 %/K (0.015 dB/K)
Load matching
Matching measurement range
Return loss
200 MHz to 3 GHz
3 GHz to 4 GHz
VSWR
200 MHz to 3 GHz
3 GHz to 4 GHz
0 dB to 23 dB
0 dB to 20 dB
>1.15
>1.22
Minimum forward power
specs met from 0.2 W 0.03 W
Error limits for matching
measurements
dB
0510
15
20
25
Return loss
0.2 GHz to 3 GHz
3 GHz to 4 GHz
-4
-2
0
2
4
6
Measurement error
dB

Table of Contents

Related product manuals