EasyManua.ls Logo

Rohde & Schwarz R&S FSH Series - Page 229

Rohde & Schwarz R&S FSH Series
245 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S FSH Field-Strength Measurement with Isotropic Antenna
1145.5973.12 4.129 E-11
bandwidth. By applying the narrow resolution bandwidth, it simulates a steep channel filter to prevent
emissions from outside the channel from affecting the measurement result.
The R&S FSH offers default settings for the 3 GPP WCDMA, cdmaOne and CDMA2000 1x
transmission systems that free you from having to enter analyzer settings. However, user-specific
channel settings are also possible that adapt the R&S FSH to other transmission systems.
Operation:
Press the CHANNEL POWER key.
The R&S FSH will open the measurement function
menu.
To exit the channel power menu, press the
SPECTRUM softkey
The R&S FSH will display the softkey menu for setting the channel power measurement. It indicates the
channel bandwidth in the measurement diagram by means of two vertical lines. It displays the
measured resultant field strength in large characters at the bottom of the diagram.
Channel bandwidth
Standard
Resultant field
strength
Channel bandwidth
Transducer active
The default power measurement setting is for 3GPP WCDMA signals.