EasyManua.ls Logo

Rohde & Schwarz R&S FSH Series - Page 79

Rohde & Schwarz R&S FSH Series
245 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation in Receiver Mode R&S FSH
1145.5973.12 2.24 E-11
Scanning in the receiver mode:
In the receiver mode, the R&S FSH can scan across a defined number of frequencies and graphically
display the results. It performs a measurement at each frequency for the defined measurement time.
! Press the SPAN softkey.
! Press the FREQ SCAN softkey.
The R&S FSH switches to the scan mode and displays the measurement levels at the individual
frequencies as vertical lines.
! Press the SCAN START softkey.
! Enter the start frequency for the scan.
! Press the SCAN STOP softkey.
! Enter the stop frequency for the scan.
! Press the SCAN STEP softkey.
! Enter the step size for the scan.
It is also possible to scan the frequencies of a channel table. This requires activating a channel table as
follows:
! Press the FREQ softkey.
! Press the CHANNEL MODE softkey.
The R&S FSH now performs a measurement at the frequencies of the channel table.