EasyManua.ls Logo

Rohde & Schwarz ZNB20 - Page 1016

Rohde & Schwarz ZNB20
1498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
R&S
®
ZNB/ZNBT
1016User Manual 1173.9163.02 ─ 54
Suffix:
<Ch>
.
Channel number
<Bus> RFFE bus number
Parameters:
<Voltage> Range: 0 to 2.5 V
Increment: 0.001 V
Default unit: V
Manual operation: See "CLK, VIO, VLow, VHigh" on page 518
CONTrol<Ch>:RFFE<Bus>:TEST:DATA
<Test Data Voltage>
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk <Test Clock Voltage>
CONTrol<Ch>:RFFE<Bus>:TEST:VIO <OutputVoltage>
These commands define the output voltages for the voltage/current measurements on
the RFFE pins.
Note: The voltages for DATA and CLOCk are always identical; their values cannot be
set independently.
The output voltages are applied using CONTrol<Ch>:RFFE:TEST:OUTPut, the volt-
age/current measurements are started using CONTrol<Ch>:RFFE:TEST:SENSe:
TRIGger.
Suffix:
<Ch>
.
Channel number
<Bus> RFFE bus interface 1 or 2
Parameters:
<OutputVoltage> Range: 0 V to 2.5 V
Increment: 1 mV
*RST: 0 V
Default unit: V
Example:
:CONTrol:RFFE1:TEST:DATA 1V
:CONTrol:RFFE1:TEST:CLOC?
DATA and CLOCK are set simultaneously, so this should return
1V
:CONTrol:RFFE1:TEST:VIO 1V
:CONTrol:RFFE2:TEST:CLOCk 2V
:CONTrol:RFFE2:TEST:DATA?
DATA and CLOCK are set simultaneously, so this should return
2V
:CONTrol:RFFE2:TEST:VIO 2V
Options: R&S ZN-B15/Z15 Var. 03
Manual operation: See "Output Voltage" on page 520
SCPI Command Reference

Table of Contents

Related product manuals