EasyManua.ls Logo

Rohde & Schwarz ZNB20 - Table of Contents

Rohde & Schwarz ZNB20
1498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
R&S
®
ZNB/ZNBT
1000User Manual 1173.9163.02 ─ 54
CONTrol<Ch>:RFFE<Bus>:SETTings:FREQuency......................................................... 1015
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:IO......................................................... 1015
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:LOW......................................................1015
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:HIGH.....................................................1015
CONTrol<Ch>:RFFE<Bus>:TEST:DATA......................................................................... 1016
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk.......................................................................1016
CONTrol<Ch>:RFFE<Bus>:TEST:VIO............................................................................1016
CONTrol<Ch>:RFFE<Bus>:TEST:DATA:RANGe............................................................. 1017
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk:RANGe...........................................................1017
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:RANGe................................................................1017
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk:SHUNt?..........................................................1017
CONTrol<Ch>:RFFE<Bus>:TEST:DATA:SHUNt?............................................................ 1017
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:SHUNt?...............................................................1017
CONTrol:RFFE<Bus>:TEST:DATA:VOLTage?................................................................. 1018
CONTrol:RFFE<Bus>:TEST:CLOCk:VOLTage?...............................................................1018
CONTrol:RFFE<Bus>:TEST:VIO:VOLTage?....................................................................1018
CONTrol:RFFE<Bus>:TEST:DATA:CURRent?................................................................ 1018
CONTrol:RFFE<Bus>:TEST:CLOCk:CURRent?.............................................................. 1018
CONTrol:RFFE<Bus>:TEST:VIO:CURRent?................................................................... 1018
CONTrol<Ch>:SEGMent<Nr>:SEQuence:COUNt?..........................................................1018
CONTrol<Ch>:SEGMent<Nr>:SEQuence:CLEar:ALL...................................................... 1019
CONTrol<Ch>:SEGMent<Nr>:SEQuence<Nr>:DELay..................................................... 1019
CONTrol<Ch>:SEGMent<Nr>:SEQuence<Nr>:GPIO<Port>:VOLTage...............................1019
CONTrol<Ch>:SEGMent<Nr>:SEQuence<Nr>:RFFE<Bus>:COMMand:DATA................... 1020
CONTrol<Ch>:SEQuence:CLEar:ALL............................................................................ 1021
CONTrol<Ch>:SEQuence:COUNt?................................................................................1021
CONTrol<Ch>:SEQuence<Nr>:DELay........................................................................... 1021
CONTrol<Ch>:SEQuence<Nr>:GPIO<Port>:VOLTage..................................................... 1022
CONTrol<Ch>:SEQuence<Nr>:RFFE<Bus>:COMMand:DATA..........................................1022
CONTrol:AUXiliary:C[:DATA] <DecValue>
Sets or queries a channel-dependent eight-bit decimal value to control eight independ-
ent output signals at the USER PORT connector (lines 8, 9, 10, 11 and lines 16, 17, 18,
19). The output signals are 3.3 V TTL signals which can be used to differentiate
between up to 255 independent analyzer states. CONTrol:AUXiliary:C[:DATA]
itself does not change the analyzer state.
Channel bit definition and activation
The channel bits have the following properties:
After a *RST of the analyzer all channel bits (including the value for the active,
sweeping channel no. 1) are set to zero; no signal is applied to pins 8 to 11 and 16
to 19 of the USER PORT connector.
The value defined with CONTrol:AUXiliary:C[:DATA] is assigned to the
active channel (INSTrument:NSELect <Ch>).
The signals at the USER PORT connector reflect the channel bits of the measur-
ing channel, i.e. the channel for which the analyzer performs a sweep. This chan-
nel is not necessarily identical with the active channel.
SCPI Command Reference

Table of Contents

Related product manuals