GUI Reference
R&S
®
ZNB/ZNBT
603User Manual 1173.9163.02 ─ 54
Adjust Impedance Mismatch
If checked, the SFD tool performs automatic impedance adjustments.
Remote command:
CALCulate:FMODel:SFD<Ph_pt>:AUTO on page 834
6.13.5.8 EZD Advanced Settings
Allows you to specify advanced parameters for the EZD tool.
Generate Side 1/Generate Side2
If checked (default), the tool generates the deembedding file for side 1 / side 2.
Remote command:
CALCulate:FMODel:EZD<Ph_pt>:GENerate:SIDE<1|2>
DC Extrapolation
If unchecked (default), the touchstone data of the generated deembedding file reach
down to the start frequency of the instrument sweep. If checked, the EZD tool adds
(extrapolated) S-parameter data for f = 0.
Remote command:
CALCulate:FMODel:EZD<Ph_pt>:DCEXtrapolat
6.13.6 Port Sets Tab
Selects transformation networks for deembedding/embedding arbitrary port sets,
defines their parameters, assigns them to a port set and enables embedding.
Use the complementary dock widget to create the required port sets and to activate or
deactivate dembedding/embedding for selected port sets (see Chapter 6.13.1.4, "Port
Sets Panel", on page 574).
Background information
Refer to Chapter 5.6.2.5, "Port Pair De-/Embedding", on page 195 and Chap-
ter 5.6.2.6, "Port Set De-/Embedding", on page 196.
Offset Embed Softtool