MIG-200MI / MIG-250MI
Environment
1. The machine can perform in environments where conditions are dry with a maximum
humidity level of 90% and an ambient temperature between -10 to +40 degrees centigrade.
2. Avoid welding in direct sunshine or a wet/damp environment. If the machine comes into
contact with water, do not use the machine until it has been fully inspected by a qualied
professional.
3. Do not use the machine in an environment where the air is polluted with conductive dust.
Health and Safety
Technical Data
MIG-200MI MIG-250MI
Power Voltage (V) Single Phase AC230V±15% Single Phase AC230V±15%
Frequency (HZ) 50/60 50/60
Rated Input Current (A) 28 36.4
Output Current MIG (A) 50-200 50-250
Output Current MMA (A) 20-200 20-250
Output Voltage (V) 16.5-24 16.5-26.5
Duty Cycle (%) 60 60
Power Factor 0.93 0.93
Efciency (%) 85 85
Wire Machine Compact Compact
Wire Speed (M/Min) 2.5-13 2.5-13
Post Puff (S) 1 1
Wire Spool Diameter (mm) 150 150
Wire Diameter (mm) 0.6-1 0.6-1
Applied Welding Rod (mm) 1.6-4 1.6-5
Housing Shielding Grade IP21 IP21
Insulation Grade F F
Suitable Wire Thickness (mm) 0.8 and above 0.8 and above