MIDI Implementation
12
40 01 1B 00 00 01 00–18 VOICE RESERVE Part12 00 0
40 01 1C 00 00 01 00–18 VOICE RESERVE Part13 00 0
40 01 1D 00 00 01 00–18 VOICE RESERVE Part14 00 0
40 01 1E 00 00 01 00–18 VOICE RESERVE Part15 00 0
40 01 1F 00 00 01 00–18 VOICE RESERVE Part16 00 0
* The sum total of voices in the voice reserve function be equal or less than 64. For compatibility with other GS models, it is recommended that the maximum polyphony be
equal or less than 24.
40 01 30 00 00 01 00–07 REVERB MACRO 00: Room 1 04 Hall 2
01: Room 2
02: Room 3
03: Hall 1
04: Hall 2
05: Plate
06: Delay
07: Panning Delay
40 01 31 00 00 01 00–07 REVERB CHARACTER 0–7 04 4
40 01 32 00 00 01 00–07 REVERB PRE-LPF 0–7 00 0
40 01 33 00 00 01 00–7F REVERB LEVEL 0–127 40 64
40 01 34 00 00 01 00–7F REVERB TIME 0–127 40 64
40 01 35 00 00 01 00–7F REVERB DELAY FEEDBACK 0–127 00 0
* REVERB MACRO is a macro parameter that allows global setting of reverb parameters. When you select the reverb type with REVERB MACRO, each reverb parameter will be
set to the most suitable value.
* REVERB CHARACTER is a parameter that changes the reverb algorithm. The value of REVERB CHARACTER corresponds to the REVERB MACRO of the same number.
40 01 38 00 00 01 00–07 CHORUS MACRO 00: Chorus 1 02 Chorus 3
01: Chorus 2
02: Chorus 3
03: Chorus 4
04: Feedback Chorus
05: Flanger
06: Short Delay
07: Short Delay (FB)
40 01 39 00 00 01 00–07 CHORUS PRE-LPF 0–7 00 0
40 01 3A 00 00 01 00–7F CHORUS LEVEL 0–12 40 64
40 01 3B 00 00 01 00–7F CHORUS FEEDBACK 0–127 08 8
40 01 3C 00 00 01 00–7F CHORUS DELAY 0–127 50 80
40 01 3D 00 00 01 00–7F CHORUS RATE 0–127 03 3
40 01 3E 00 00 01 00–7F CHORUS DEPTH 0–127 13 19
40 01 3F 00 00 01 00–7F CHORUS SEND LEVEL TO REVERB 0–127 00 0
* CHORUS MACRO is a macro parameter that allows global setting of chorus parameters. When you use CHORUS MACRO to select the chorus type, each chorus parameter will
be set to the most suitable value.
40 03 00 00 00 02 00–7F EFX TYPE (MSB, LSB) 00 00–7F 7F 00 00 Thru
* For details on each type, refer to “5. Eect List.”
* This EFX Type is current EFX type of this system. When part EFX type is same to this EFX type, that part connect to EFX.
40 03 03 00 00 01 00–7F EFX Parameter 1
40 03 04 00 00 01 00–7F EFX Parameter 2
40 03 05 00 00 01 00–7F EFX Parameter 3
40 03 06 00 00 01 00–7F EFX Parameter 4
40 03 07 00 00 01 00–7F EFX Parameter 5
40 03 08 00 00 01 00–7F EFX Parameter 6
40 03 09 00 00 01 00–7F EFX Parameter 7
40 03 0A 00 00 01 00–7F EFX Parameter 8
40 03 0B 00 00 01 00–7F EFX Parameter 9
40 03 0C 00 00 01 00–7F EFX Parameter 10
40 03 0D 00 00 01 00–7F EFX Parameter 11
40 03 0E 00 00 01 00–7F EFX Parameter 12
40 03 0F 00 00 01 00–7F EFX Parameter 13
40 03 10 00 00 01 00–7F EFX Parameter 14
40 03 11 00 00 01 00–7F EFX Parameter 15
40 03 12 00 00 01 00–7F EFX Parameter 16
40 03 13 00 00 01 00–7F EFX Parameter 17
40 03 14 00 00 01 00–7F EFX Parameter 18
40 03 15 00 00 01 00–7F EFX Parameter 19
40 03 16 00 00 01 00–7F EFX Parameter 20
* Each parameter will be changed by EFX type. Refer to EFX Parameter Map.