Troubleshooting
A-6
MV-8800 Appendices
Problems with effects
Problems with sampling
Problem
Cause
An effect is not applied
Could the effect be turned off (disabled)?
In the EFFECTS screen (Screen Guide; p. 229), turn on (enable) the effect that you want to
use.
Are the various settings of the effect appropriate?
Check the settings in the EFFECTS EDIT screen (Screen Guide; p. 231).
Could the send level of the signal from each part or audio track be turned down?
In each MIXER screen, check the DlyCho Send or Reverb Send settings.
MIXER (AUDIO TRACK) screen (Screen Guide; p. 235)
MIXER (INSTRUMENTS PART) screen (Screen Guide; p. 236)
MIXER (AUX/FX/AUDIO PHRASES/INPUT) screen (Screen Guide; p. 237)
Is the MFX (multi-effect) routing appropriate?
In the EFFECTS screen (Screen Guide; p. 229), check the Routing setting.
Problem
Cause
Can’t sample
Is there free space in wave memory?
Check the Wave Memory status.
SAMPLING screen (Screen Guide; p. 209), RESAMPLING screen (Screen Guide; p. 209)
If there are unused samples, delete them.
SAMPLE MANAGER screen (Screen Guide; p. 169)
Have you made the appropriate settings to initiate sampling?
In the SAMPLING screen (Screen Guide; p. 209), check the Start Trigger setting.
Sampling ends
prematurely
Could you be running out of wave memory?
Check the Wave Memory status.
SAMPLING screen (Screen Guide; p. 209), RESAMPLING screen (Screen Guide; p. 209)
If there are unused samples, delete them.
SAMPLE MANAGER screen (Screen Guide; p. 169)
Could you have made settings to stop sampling?
In the SAMPLING screen (Screen Guide; p. 209), check the Stop Trigger setting.
When a sample is
assigned to a partial or
audio phrase and played,
it is lower in volume than
when it was originally
sampled
The overall volume of the sampler is lowered to prevent distortion from occurring in the out-
put due to filter settings (or other causes) when large numbers of notes are played simul-
taneously.
As appropriate for the sound you’re using or the number of simultaneously played notes, you
can adjust the GLOBAL screen (Screen Guide; p. 173) Sampler Output Gain setting to a
suitable value.
Noise or distortion is
heard in the sampled
sound
Is the input sensitivity set appropriately?
Use the SENS knob to adjust the input sensitivity so that the level meter moves within a range
of -12–0 dB.