control the overall output level present at the Output and Headphone output jacks for
amplification and monitoring.
(F) CLEAR/RESET Button
Depending on the MODE Selector (B) position, and the RUN/STOP condition, this
button will perform the following functions:
When stopped in the PATTERN WRITE Mode, this button will clear an entire rhythm
pattern by pressing it while holding the SELECTOR Switch (K) down for the Rhythm
Pattern to be cleared. The scale and number of Steps in the Rhythm Pattern will not
change.
[Additionally, when running in pattern write mode, it will clear individual instruments
from the pattern if you hold it down - ed]
When running in the PATTERN PLAY Mode, this button has no effect.
When stopped in the TRACK PLAY Mode or TRACK WRITE Mode, this button
Resets the TR-606 so that it will begin with bar 1 of the Track selected when the RUN
button (H) is pressed. If this button is pressed while the FUNCTION button (J) is held
down, the D.C. bar will be displayed using the LED indicators (L).
When running in the TRACK PLAY Mode, this button has no effect.
When running in the TRACK WRITE Mode, this button writes the current bar to
memory as a D.C. bar, signalling the end of the track.
(G) BATTERY CHECK/RUN Indicator
This LED will light to indicate the Run condition. If the indicator flashes or does not
illuminate in the Run condition even if the other LEDs still illuminate, replace all of
the batteries with new ones.
(H) RUN/STOP Button
This button alternately starts and stops the running of rhythms, and will perform
differently according to the position of MODE Selector (B).
(I) SCALE Selector
This selector determines the number of steps assigned to each quarter note beat, as
shown by the relationship between the graphic illustration to the right of the SCALE
Selector (I) and the 16 SELECTOR Switches (K) below. The position of the SCALE
Selector is memorized into computer memory when the FUNCTION button (J) is
pressed while running in the PATTERN WRITE Mode.
(J) FUNCTION Button
This button will perform different functions according to the RUN/STOP condition
and the MODE Selector (B) position.
When stopped in the PATTERN WRITE Mode, this button has no effect.