USER MANUAL
19
17
.BEARING LUBRICATION
All of the bearings in this product are lubricated with a sufcient
amount of high grade lubricant for the life of the unit under normal
operating conditions. Therefore, no further lubrication is required.
.REPLAING THE AIR FILTER
1) Turn the air lter cover counterclockwise approximately one-
quarter turn.
2) Remove the cover
3) Remove the air lter.
4) Install new air lter.
5) Replace the air lter cover and secure it by turning it clockwise.
.CHANGING THE OIL
Replace the oil after the rst 10 hours of operation and every
100 hours following the oil change.
The sight glass, located above the tank, indicates the oil level
and lets the operator see at a glance if oil should be added.
1) Place as suitable container underneath the drain to collect
used oil.
2) Remove the drain plug with an 8 mm socket or wrench.
3) When the used oil has drained, reinstall the drain plug and
tighten with the wrench.
4) Unscrew the cap of oil ll hole.
5) To rell, use a funnel to pour oil into the hole. Rell only with
synthetic oil l SAE 5W40.