AIR COMPRESSOR
20
NOTE:
Avoid relling with too much oil. Ensure that the level of the oil does
not exceed the top of the red dot at sight glass. The recommended
amount of oil for relling is 250ml.
1) Tighten the cap securely into the ll hole.
.ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing of as waste. The
machine, accessories and packaging should be sorted for envi-
ronmental-friendly recycling.
.TROUBLESHOOTING
PROBLM CAUSE POSSIBLE SOLUTION
Compressor will not run
Loss of power or overheating
Check for proper use of
extension cord
NO electrical power
Check to be sure unit is
plugged in
Blown shop/house fuse Check fuse/ breaker
Shop/house breaker open
Replace shop/house blow
fuse
Current limiting protector
open
Reset shop/house breaker,
determine why problem
happened
Pressure switch bad Motor will restart when cool
Tank is full of air
Compressor will tum on
when tank
Pressure drops to cut- in
pressure
Motor hums but cannot run
or runs slowly
Low voltage Check with voltmeter
Wrong gauge wire or length
of extension cord
Check for proper gauge wire
and cord length
Shorted or open motor
winding
Take compressor to service
center
Defective check valve or
unloader
Take compressor to service
center
Current limiting protector
Protector cuts out repeatedly
LOW voltage Check with voltmeter
Lack of proper ventilation/
room temperature too high
Move compressor to well-
ventilated area
Wrong gauge wire or length
of extension cord
Check for proper gauge wire
and cord length
18