8-5 GROW OUT (Output)
GROW OUT output is turned ON when the motor changes from a stationary state to the speed set
at High Speed trimmer. Therefore, by using the number of pulses from acceleration to GROW
OUT output duration, it is possible to calculate deceleration time.
This feature makes the driver control only by setting total pulse using RC-204A and RC-207A.
Fig.11 GROW OUT Output
8-6 CLOCK OUT (Output)
The CLOCK OUT is clock pulse output terminal.
You can select output pulse from among 1 to 80 pulses/step by using dip switches.
The duty of output clock pulse is approx. 40 to 60%.
Note: The excitation method of motor is any of 50, 64, or 80 microsteps/step.
8-7 ALARM (Output)
This terminal puts out a L signal when Overheating protection circuit is in operation.
(Open collector output is turned ON.)
9.ALARM LED
This will light when Overheating protection circuit is in operation.
SPEED
TIME
2 1