Technical Specifications
AYC-Fx4 and AYC-Gx4 family manual Page 7
2. Technical Specifications
Electrical Characteristics
Linear type – recommended
Operating voltage
range
5 - 16VDC (when used as a controller, provided by
the secure application appurtenance)
Input current standby
(12VDC)
75mA 105mA 75mA 105mA
Input current max
(16VDC)
110mA 140mA 110mA 140mA
Open collector, active low, 32mA max sink current
Up to 500ft (150 meters) using an 18AWG cable
(80mm)
Proximity card
modulation
N/A ASK at 125
KHz
N/A ASK at 125
KHz
Proximity card
compatibility
N/A EM cards N/A EM cards
(Reader)
N/A 26-bit
Wiegand,
or Clock &
N/A 26-bit
Wiegand, or
Clock &
Format (Reader)
Programmable PIN code formats
Data1/C1, Data0/C2—open collector, 5V