RECOMMENDED OPERATIONS
FREQUENCY
Replace compressor oil
After the first 50 hours
Check the torque of screws and bolts on compressor and engine silent-blocks
Every 50 hours
Check the torque of all screws and bolts
Every 100 hours
Check tightness of all pipe/tubing connections
Every 100 hours
Replace compressor air filter
After 500 hours
Replace compressor oil filter
After 500 hours or after a
long storage period (9-12
months),
whichever comes first
Replace compressor oil
After 1500 hours
Replace oil separator filter element
After 2000 hours
Check-up by "authorized ROTAIR" service
Every 3000 hours
Check readability of the nameplate Annually
Control valves serviced by "authorized ROTAIR" service Biannually
The ROTAIR S.P.A. disclaims any responsibility for the failure to comply with maintenance requirements in the
table above.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotair Dustless Blasting D185T4F-DB and is the answer not in the manual?

Rotair Dustless Blasting D185T4F-DB Specifications

General IconGeneral
BrandRotair
ModelDustless Blasting D185T4F-DB
CategoryAir Compressor
LanguageEnglish

Related product manuals