13.4-3 FUSE REPLACEMENT
Fuse replacement should be performed when one or both fuses are damaged.
To replace the fuse, proceed as follows:
1) Stop the machine
2) Open the hood
3) Open the fuse box
4) Pull the fuse to be replaced with tweezers (to fuse 15 A) or remove the nuts for the 40 A fuses
5) Once the fuse has been removed, observe the internal filament. This must be intact to function
properly, and if it is intact, reinstall the fuse
6) In the event of a open/broken fuse, replace it by choosing a fuse with identical ratings. The ratings of
the fuses are described in Section 8.3 of this manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotair Dustless Blasting D185T4F-DB and is the answer not in the manual?

Rotair Dustless Blasting D185T4F-DB Specifications

General IconGeneral
BrandRotair
ModelDustless Blasting D185T4F-DB
CategoryAir Compressor
LanguageEnglish

Related product manuals