13.2 Maintenance program
In this program are listed all the maintenance items and the frequency of which they must be executed
on the various components of the machine. Such maintenance is essential for the proper functioning of
the machine and its mechanical durability over time.
RECOMMENDED OPERATIONS
FREQUENCY
Check the compressor oil level
Daily
Check engine oil level (refer to the manufacturer's manual)
Daily
Check Coolant Level
Daily
Check fuel level and top off (if necessary)
Daily
Check oil or fuel leakage
Daily
Check operation indicator\warning lights
Daily
Check the readability of measuring instruments
Daily
General cleaning operations
Daily
Check for obstructions to the ventilation system
Daily
Check air filter in dusty work conditions
Daily
Check operation trailering lights and license plate lights (only for the approved
road version)
Daily
Check the compressor air filter
Weekly
Check the engine air filter
(Ref. Manual of the engine
manufacturer)
Check the battery electrolyte level
Monthly
Check tire pressure
Monthly
Check belt tension
Three months
Check speed controls at the minimum and maximum engine RPM
Three months
Check the operation of the safety valve
Three months
Clean the oil cooler
Three months
Check the oil recovery nozzle
Three months
Drain the fuel tank
Three months
Replace diesel fuel pre-filter
Every 500 hours
Check the operation of the braking system
Three months
Check the parking brake if equipped
Three months
Change engine oil
Ref. Manual of the engine
manufacturer
Replace compressor oil filter
After the first 50 hours

Table of Contents

Questions and Answers: