13
Overhead
Hose
Power Unit
(Short) Hose
Crimped Hose
Sleeve (Typical)
Branch Tee
Push nuts hold bolts to brackets.
Fill Breather Cap
Use (4)5/16"-18NC
x1-1/2" lg. Flanged
Locking HHCS
and Nuts
Fig. 9
9. Power Unit: Put the (4) 5/16”-18NC x 1-1/2” anged
Locking HHCS thru holes in power unit bracket using Push-
Nuts to hold in place, Fig. 9. Mount unit with motor up to
column bracket and install (2) 5/16” anged locking nuts.
Install and hand tighten Branch Tee to pump until O-ring is
seated. Continue to tighten the locknut to 10-15 ft-lbs (14-20
Nm), or until the nut and washer bottom out against the
pump manifold. NOTE: You may still be able to rotate the
Branch Tee. This is acceptable unless there is seepage at
the O-ring. If so, slightly tighten the locknut.
Over tightening locknut may tear O-ring or
distort threads in pump manifold outlet.
Fig. 10
3/8"-16NC Flanged HHCS
and Serrated Locknuts
P/N 40664
10. Hoses: Clean adapters and hose. Inspect all threads
for damage and hose ends to be sure they are crimped, Fig.
10. Install hose and hose clamps, Fig. 11, Fig.12 & Fig. 16.
Flared Fittings Tightening Procedure
1. Screw the ttings together nger tight. Then, using the
proper size wrench, rotate the tting 2-1/2 hex ats.
Flare seat MUST NOT rotate when
tightening. Only the nut should turn.
2. Back the tting off one full turn.
3. Again tighten the ttings nger tight; then using a
wrench, rotate the tting 2-1/2 hex ats. This will
complete the tightening procedure and develop a
pressure tight seal.
Overtightening will damage tting resulting in
uid leakage.