7
Concrete and Anchoring:
If you are installing a seismic lift, consult with a structural
engineer and manufacturer’s representative for concrete
and anchoring requirements (varies by location). Fig. 4 and
the below table apply to non-seismic lifts only.
Fig. 4
Run nut down just below impact
section of bolt. Drive anchor
into hole until nut and washer
contact base.
Drill holes using 3/4” carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
Manually hand tighten
nut with torque wrench
to 110 ft.-lbs. (149 Nm).
10K 2-Post Lift Anchor Installation Reference Guide
Anchor: Min
Concrete
Thickness
Min Edge
Distance
Min Anchor
Embedment
Installation
Anchor Torque
(ft-lbs)
Min Concrete PSI
Strength - For All
Standards
Concrete pad
Size If Concrete
Does Not Meet
Requirements
Maintenance
Torque Values**
(ft-lbs)
SEISMIC
Hilti Kwik Bolt I
(3/4" x 5-1/2")
4-1/4"
(108mm)
6-1/4"
(159mm)
3-1/4"
(83mm)
110
(149Nm)
3000
(20684 kPa)
4'x4'x8"
(1219 x 1219 x
152mm)
65
(88Nm)
Varies by
location
consult with
your structural
engineer and
manufacturer’s
representative.
Power-Stud+SD1 4-1/4"
(108mm)
6-1/4”
(159mm)
3-1/4"
(83mm)
110
(149Nm)
3000
(20684 kPa)
4'x4'x8"
(1219 x 1219 x
152mm)
65
(88Nm)
Hilti HY200
Epoxy (with HAS
threaded rod)
3/4" Dia.
5"
(134mm)
2 1/4"
(57mm)
3-1/2"
(89mm)
100 (135Nm) / less
than 2-1/8" edge
distance use
Torque Value of
30 ft-lbs (41Nm)
3000
(20684 kPa)
4'x4'x8"
(1219 x 1219 x
152mm)
N/A
*The supplied concrete fasteners meet the criteria of the American National Standard
“Automotive Lifts - Safety Requirements for Construction, Testing, and Validation” ANSI/ALI ALCTV-2011, and the lift owner is responsible for all charges
related to any additional anchoring requirements as specied by local codes. Contact customer service for further information at: 800.640.5438