[2] - Anti-legionella system
If no hot water is used for several days and the storage temperature of the HPSU compact does not reach at least 60 °C,
for hygiene reasons (Legionella protection) it is periodically heated up to above 60 °C once.
The following setting options are available:
[2-00] Operating interval: Day(s) of the week on which the "Legionella protection" function should be started.
[2-01] Status: 0 = Function "Anti-legionella system" is switched off, 1 = Function "Anti-legionella system" is switched on.
[2-02] Starting time: Starting time, the day on which the function "Anti-legionella system" is started.
[2-03] Target value: Disinfection temperature to be reached.
[2-04] Holding time: Length of time for which the disinfection temperature should be maintained.
NOTE:
For colder outside temperatures (Lo_A), the value Lo_Ti must be higher that the value Hi_Ti, as hotter
water is required.
With warmer outside temperatures (Hi_A) the value Hi_Ti must be lower that the value Lo_Ti, as less hot
water is required.
T
t
Target water temperature
T
A
Ambient temperature (outside air)
'
T
Adjustment value
Fig. 4-2 View of the control system with active "Weather-dependent set value regulation"
WARNING!
The settings of the function "Anti-legionella system" must always be configured in accordance with the
country-specific laws.
tTime
T
DHW
Hot water temperature
T
H
Disinfection temperature [2-03]
T
U
Target temperature for hot water (as set on main control
unit (HPR1))
Fig. 4-3 View of the control system with active "Anti-legionella system"

Other manuals for Rotex HPSU compact (V5)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotex HPSU compact (V5) and is the answer not in the manual?

Rotex HPSU compact (V5) Specifications

General IconGeneral
BrandRotex
ModelHPSU compact (V5)
CategoryHeat Pump
LanguageEnglish

Related product manuals