10 x Technical data
FA ROTEX HPSU compact (V5) • 
75
Performance data
Type exterior heat pump unit
RRLQ004CA
V3
RRLQ006CA
V3
/RRLQ008
CAV3
RRLQ004CA
V3
RRLQ006CA
V3/RRLQ008
CAV3
Nominal heat output A-7/W35 kW 4.26 5.29 / 5.53 4.26 5.29 / 5.53
Nominal heat output A2/W35 kW 3.47 4.6 / 5.51 3.47 4.6 / 5.51
Nominal heat output A7/W35 kW 4.53 6.06 / 7.78 4.53 6.06 / 7.78
Nominal heat output A10/W35 kW 5.2 6.6 / 8.4 5.2 6.6 / 8.4
Nominal cooling output A35/W18 kW 4.42 5.22 / 5.22 4.42 5.22 / 5.22
Nominal cooling output A35/W7 kW 4.03 4.46 / 4.64 4.03 4.46 / 4.64
Nominal COP A-7/W35 2.85 2.73 / 2.78 2.85 2.73 / 2.78
Nominal COP A2/W35 4.07 3.64 / 3.54 4.07 3.64 / 3.54
Nominal COP A7/W35 5.23 4.65 / 4.6 5.23 4.65 / 4.6
Nominal COP A10/W35 5.53 4.95 / 4.9 5.53 4.95 / 4.9
Nominal EER A35/W18 4.21 3.65 / 3.65 4.21 3.65 / 3.65
Nominal EER A35/W7 2.85 2.51 / 2.51 2.85 2.51 / 2.51
Max. heating output A-7/W35 kW 4.6 5.3 / 6.4 4.6 5.3 / 6.4
Max. heat output A2/W35 kW 4.8 6.4 / 7.7 4.8 6.4 / 7.7
Max. heat output A7/W35 kW 5.1 8.4 / 10.2 5.1 8.4 / 10.2
Max. heat output A10/W35 kW 5.2 8.8 / 10.5 5.2 8.8 / 10.5
Max. cooling output A35/W18 kW 5.9 7.3 / 8.4 5.9 7.3 / 8.4
Max. cooling output A35/W7 kW 4.5 5.5 / 6.4 4.5 5.5 / 6.4
1) T
CW
Cold water input temperature = 10 °C
T
DHW
Hot water draw-off temperature = 40 °C
T
S
Storage target temperature
(charge state before drawing off)
2) With a reference spacing of 1 m.
3) Number of individual wires in the conn
ection cable, including protective
earth. The cross-section of the individual lines is dependent on the current
load, the length of the connection cable and the respective legal provi-
sions.
Tab.
10-1 Basic data ROTEX HPSU compact 304/308
Type ROTEX HPSU compact
304 DB 308 DB 304 BIV 308 BIV

Table of Contents