EP Series User Manual
53
Segment 13 wait time after completion of
displacement
Segment 14 displacement maximum speed, unit: rpm
Segment 14 displacement acceleration and
deceleration, unit: r/s^2
Segment 14 wait time after completion of
displacement
Segment 15 displacement maximum speed, unit: rpm
Segment 15 displacement acceleration and
deceleration, unit: r/s^2
Segment 15 wait time after completion of
displacement
3.3.17. Homing control mode settings [287
~
295]
Table 3-29 Register details [287~295]
Homing start control method setting
The homing function is prohibited.
Use the IN terminal whose IN input
function is "Start homing" to trigger the
mechanical return-to-origin function.
Use the IN terminal whose IN input
function is "Start homing" to trigger the
electrical return-to-origin function.
Electrical return-to-origin is generally
used after mechanical return-to-origin,
and no sensor input signal is required.
Run directly according to the absolute
position and return to the position
command set by the parameter
P293/294. After the electrical
return-to-origin is completed, the
parameter P8/9 is equal to the
parameter P293/294.
Power-on automatic mechanical
return-to-origin.