T60-IO User Manual -1-
szruitech.com
1
T60-IO Closed Loop Stepper Driver
User Manual
Shenzhen Rtelligent Mechanical Electrical Technology Co.,ltd

Questions and Answers

  • M
    Matthew BrownAug 2, 2025
    What to do if my Rtelligent Control Unit motor does not work?
    • J
      Jared NashAug 2, 2025
      If your Rtelligent Control Unit motor isn't working, first check if the power indicator is off and ensure the power supply circuit is providing normal power. If the motor rotor is locked, the pulse signal might be weak, so increase the signal current to 7-16mA. Also, the driver might be protected, in that case, solve the alarm and re-power the device. Another possible reason is an enable signal problem, try pulling up or disconnecting the enable signal. Finally, check whether the upper computer has pulse output, as the command pulse might be incorrect.
  • J
    jamesholmesAug 7, 2025
    Why is the position or speed wrong on my Rtelligent T60-IO Control Unit?
    • A
      Amy BergerAug 7, 2025
      If the position or speed is wrong, it might be due to signal interference. Ensure reliable grounding to eliminate interference. Another cause could be incorrect command input; check the upper computer instructions to ensure the output is correct. Also, verify the Pulse per revolution setting by checking the DIP switch status and correctly connecting the switches. If the encoder signal is abnormal, it might be necessary to replace the motor.
  • J
    Joseph GrantAug 11, 2025
    What to do if the Rtelligent T60-IO Control Unit motor is out of tolerance?
    • M
      Mark HowardAug 11, 2025
      If the motor is out of tolerance, it could be due to several reasons. The acceleration and deceleration time might be too short, so reduce command acceleration or increase driver filtering parameters. Another possibility is that the motor torque is too low, in which case you should select a motor with high torque. Also, check the load weight and quality and adjust the mechanical structure if the load is too heavy. Finally, ensure that the current of power supply is sufficient.
  • C
    Cindy EspinozaAug 15, 2025
    What to do if the alarm indicator is on in Rtelligent T60-IO Control Unit?
    • A
      Amanda HamiltonAug 15, 2025
      If the alarm indicator is on, check the motor connection to ensure it is correct. Also, verify the sequence of the encoder connection. Another potential issue is the voltage being too high or too low, so check the power supply.
  • M
    Mr. Jeffery WilliamsAug 19, 2025
    Why is the steering of motor wrong in Rtelligent T60-IO?
    • B
      Brian MccarthyAug 19, 2025
      If the steering of the motor is wrong, adjust the DIP SW5 because the rotary direction of the motor might be reversed. Check the motor connection, as the motor cable might be disconnected. If the motor only operates in one direction, there might be a pulse mode error or the DIR port could be damaged.
  • S
    spenaAug 25, 2025
    What causes the Rtelligent T60-IO driver terminal short circuit?
    • R
      Robert MartinAug 25, 2025
      A short circuit between terminals can be caused by power polarity issues or an external short circuit. Check these aspects to resolve the problem.
  • S
    Stacy BlairAug 28, 2025
    What causes Rtelligent T60-IO Control Unit to be burned up?
    • H
      hortonwilliamAug 28, 2025
      If the device burned up, check whether there is any solder ball due to excessive addition of solder on the wire connections, as the internal resistance between terminals might be too large.

Summary

Product Overview

Application Environment and Installation

Environmental Requirements

Details environmental requirements for the driver's installation and operation.

Driver Installation Dimensions

Provides physical dimensions and mounting details for the driver unit.

Driver Installation Requirements

Specifies requirements for vertical/horizontal mounting, fixing, and heat dissipation.

Driver Port and Connection

Port Function Description

Details the function, grade, definition, and remarks for each driver port.

Power Supply Input

Explains the DC power supply requirements, voltage effects, and regeneration voltage.

Encoder Connection

Describes the A/B differential output encoder connection and cable requirements.

Motor Connection

Specifies the matching motor and its connection order for the T series stepper servo motor.

PUL, DIR Port: Start;Stop Command

Explains how PUL and DIR ports control motor start, stop, and direction.

ENA Port: Enable;Disable

Details the ENA port function for enabling/disabling the driver and motor free state.

ALM Port: Alarm and Arrival Output

Describes ALM port for operating status output and its reuse for brake control.

RS232 Serial Port

Details the RS232 serial port for connecting debugging software and changing parameters.

DIP Switch and Parameter Settings

Speed Setting

Provides a table for setting motor speed using DIP switches SW1, SW2, SW3, and SW4.

Motor Direction Selection

Explains how DIP switch SW5 sets the motor's running direction (clockwise/counterclockwise).

Open;Closed Loop Selection

Details how DIP switch SW8 selects between closed-loop and open-loop control modes.

Driver Working Status LED Indication

Common Faults and Troubleshooting

Appendix A: Guarantee Clause

Warranty Period

States the product warranty period is 12 months and includes free maintenance.

Warranty Exclusions

Lists exclusions from warranty coverage, such as improper connection or unauthorized changes.

Maintenance Process

Outlines the procedures for product maintenance, including contacting customer service.

Rtelligent T60-IO Specifications

General IconGeneral
BrandRtelligent
ModelT60-IO
CategoryControl Unit
LanguageEnglish