4-2-2. Local Commands of CLI
802.1x
set max-request
Syntax:
set max-request <port-range> <times>
Description:
The maximum number of times that the state machine will retransmit an EAP
Request packet to the Supplicant before it times out the authentication session.
Argument:
<port range> : syntax 1,5-7, available from 1 to 24
<times>: max-times , range 1-10
Possible value:
<port range> : 1 to 24
<times>: 1-10, default is 2
Example:
FGS-2824(802.1x)# set max-request 2 2
set mode
Syntax:
set mode <port-range> <mode>
Description:
To set up the 802.1X authentication mode of each port.
Argument:
<port range> : syntax 1,5-7, available from 1 to 24
<mode>: set up 802.1x mode
0:disable the 802.1x function
1:set 802.1x to Multi-host mode
Possible value:
<port range> : 1 to 24
<mode>: 0 or 1
Example:
FGS-2824(802.1x)# set mode 2 1
FGS-2824(802.1x)#