RuggedSwitch User Guide
Using RSH And SQL
The combination of remote shell scripting and sql commands offer a means to
interrogate and maintain large numbers of switches. Consistency of configuration
across sites may be verified by this method. The following presents a simple
example where the switches to interrogate are drawn from the file “switches”.
Figure 77 Bulk Inspections Using RSH and SQL
C:> type switches
10.0.1.1
10.0.1.2
10.0.1.3
c:\> for /F %i in (switches) do rsh %i -l admin sql select from ethportcfg where
flow_control = disabled
C:\>rsh 10.0.1.1 -l admin sql select from ethportcfg where flow_control =
disabled
Port Name Status Media Type Flow Control FEFI Link Alarms
5 Port 5 Enabled Auto Select Disabled Disabled Enabled
1 records selected
C:\>rsh 10.0.1.2 -l admin sql select from ethportcfg where flow_control =
disabled
0 records selected
C:\>rsh 10.0.1.3 -l admin sql select from ethportcfg where flow_control =
disabled
Port Name Status Media Type Flow Control FEFI Link Alarms
3 Port 3 Enabled Auto Select Disabled Disabled Enabled
7 Port 7 Enabled Auto Select Disabled Disabled Enabled
8 Port 8 Enabled Auto Select Disabled Disabled Enabled
13 Port 13 Enabled Auto Select Disabled Disabled Enabled
4 records selected