MODEL F71B/F71G/F67C/F67G/N75A/N75B
35
3. E1 Flash
A. Wiring of locating board
with controller damaged.
B. Locating board
damaged.
C. Mechanical driven
damaged.
D. Control board
damaged.
E. Wiring of motor with
controller damaged.
F. Motor damaged.
A. Replace wiring.
B. Replace locating
board.
C. Check and repair
mechanical part.
D. Replace control
board.
E. Replace wiring.
F. Replace motor.
4. E2 Flash
A. Hall component on
locating board damaged.
B. Wiring of locating board
with controller damaged.
C. Control board
damaged.
A. Replace locating
board.
B. Replace wiring.
C. Replace control
board.
5. E3 or E4
Flash
A. Control board
damaged.
A. Replace control
board.