C. Usage
After being accomplished installation, parameter setting and trail
running by professional, the valve could be put into use. In order to ensure
the quality of outlet water can reach the requirement, the user should
complete the below works:
① Ensure that there is solid salt all the time in the brine tank in the course
of using when this valve is used for softening. The brine tank should be
added the clean water softening salts only, at least 99.5% pure, forbidding
use the small salt and iodized salt.
② Test the outlet water and raw water hardness regularly. When the outlet
water hardness is unqualified, please press the and the valve will
temporarily regenerate again (It will not affect the original set operation
cycle.)
③ When the feed water hardness change a lot, you can adjust the water
treatment capacity as follow:
Press and hold both and for 5 seconds to unlock the buttons,
press , enter program set mode, through and buttons to select
“Advanced setting”, press , enter “Advanced setting” item setting mode,
through and buttons to select “Set residual water”, press ,
through and to set the required value. Press and hear a sound
“Di”, then finish the adjustment. Press twice, and turn back to service
status.
The regeneration parameters have been set when control valve left
factory. Generally, it does not need to reset. If you want enquiry and modify
the setting, you can refer to the professional application specification.