EasyManua.ls Logo

Runxin F117Q3 - Basic Setting & Usage (F116 Q3 A-01 as example)

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
20
2.2. Basic Setting & Usage (F116Q3 A-01 as
example)
A. Parameter specifications
Function Indicator
Factory
Default
Parameter
set range
Instruction
Time of Day
":"Flashes
Random
00:00~
23:59
When use, enquiry and set,the time of
day ":" flashes.
Regeneration
Time
":"Lighting
02:00
00:00
~
23:59
Regeneration time;":" lighting.
Control
Mode
/ A-01
A-01
Meter Delayed: Regenerate
will not
start although the available volume of
treated water drops to zero (0) until at
the regeneration time.
A-02
Meter Immediate
:
Regenerate
immediately when the available
volume of treated water drops to
zero(0).
Water
Treatment
Capacity
m
3
10.00
m
3
0~99.99
m
3
Water treatment capacity in one circle
(m
3
)
Backwash
Time
2- 10 0~99 Backwash time (minute)
Brine &
Slow Rinse
Time
3- 60 0~99 Brine & slow rinse time (minute)
Fast Rinse
Time
4- 10 0~99 Fast rinse time (minute)
Brine Refill
Time
5- 05 0~99 Brine refill time (minute)
Maximum
Interval
H-30 30 0~40
Regenerate at the regeneration time
even though the available volume of