MODELF67Q/F71Q/F68Q/F69Q/F116Q/F117Q
20
2.2. Basic Setting & Usage (F116Q3 A-01 as
example)
A. Parameter specifications
Function Indicator
Factory
Default
Parameter
set range
Instruction
Time of Day
":"Flashes
Random
00:00
23:59
When use, enquiry and set,the time of
day ":" flashes.
Regeneration
Time
":"Lighting
02:00
00:00
23:59
Regeneration time":" lighting.
Control
Mode
/ A-01
A-01
Meter Delayed: Regenerate
will not
start although the available volume of
treated water drops to zero (0) until at
the regeneration time.
A-02
Meter Immediate
Regenerate
immediately when the available
volume of treated water drops to
zero(0).
Water
Treatment
Capacity
m
3
10.00
m
3
099.99
m
3
Water treatment capacity in one circle
(m
3
)
Backwash
Time
2- 10 099 Backwash time (minute)
Brine &
Slow Rinse
Time
3- 60 099 Brine & slow rinse time (minute)
Fast Rinse
Time
4- 10 099 Fast rinse time (minute)
Brine Refill
Time
5- 05 099 Brine refill time (minute)
Maximum
Interval
H-30 30 040
Regenerate at the regeneration time
even though the available volume of