4.
Turn
fuel lever
"OFF".
(Fig.
13)
CHANGING
THE
FUSE
lf there
is
no DC outout while the
machine
is
running well,
you
may
need to
check
the fuse.
Change a
new 10A
glass
fuse if
it has
broken.
Glass
fuse can
buy
anyryvhere.
CHANGING/CLEANING
THE
SPARK
PLUG
1.
Stop the
generator
engine and
remove
sparkplug.
(Fig.
1a)
2.
Clear carbon
deposits off the sparkplug
with
a
steel
brush.
(Fig.
15)
3. Check
the
sparkplug for discolouration
(standard
colour:
tan).
Check
the
sparkplug
gap. (Fig.
16)
lf it is
discoloured or the
gap
is
damaged
please
replace
the
sparkplug.
0.7-0.8mm