6.1.3 The spindle motor overload cutout has intervened at the switching-on
CAUSE REMEDY
The clockwise rotation speed has been se-
lected
Press the push button to enable the clock-
wise rotation before starting the spindle
J
Open front cover Close the cover J
6.1.4 The overload cutout of the spindle motor has intervened
CAUSE REMEDY
Overload due to too much removal Reduce the removal depth J
Overload due to an excessive feeding speed Reduce the feeding speed J
Overload due to the tools Sharpen the tools or change the plates J
6.1.5 Piece surface being machined not smooth
CAUSE REMEDY
Worn tools Sharpen the tools or change the plates J