EasyManua.ls Logo

Saft 1606-1 - CLEANING; 1. Light cleaning; 2. Full cleaning

Saft 1606-1
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAFT
COMPONENT MAINTENANCE MANUAL
1606-l
CLEANING
1. Liqht cleaninq
- If a clean filtered supply of compressed air is available, do this
procedure to easily and quickly clean the cells: blow with much force
across the tops of the cells to remove all dust and mineral salts from
the box.
- To prevent short-circuits,
use a rubber tube or an insulating nozzle.
2. Full cleaninq
Disassemble the battery (Refer to
"DISASSEMBLY") and then clean all the
components.
A. Cells:
- To easily remove all the electrolyte and mineral salts from the
terminals,
the covers and the sides of the cell cases: clean in warm
water with a soft brush.
- Make sure that the vented filler cap (safety cap) is tight.
- Do not soak the cells in water.
- Rub the cell with a cloth and let dry.
B. Box:
- Clean with water,
rub with a cloth and let dry.
C. Nuts,
spring washers and links:
- Clean in warm water with a brush and let dry.
D. Packing parts and sealed insulating liner:
- Clean in warm water and let dry.
E. Vented filler caps:
- Remove the vented filler caps (Refer to "DISASSEMBLY").
- Put covers on the cell holes to keep out unwanted material.
- Soak the vented filler caps for some time (during the night, for
example) in a container of distilled water (or, if not available, in
very clean tap water).
Do this to remove all salts from the vent
hole.
24-39-06
Page 401
Apr 01/92
The document reference is online, please check the correspondence between the online documentation and the printed version.