SAFT
COMPONENT MAINTENANCE MANUAL
1606-l
TESTING AND FAULT ISOLATION
1. Testinq
For the test procedures, refer to "CHECK".
2. Fault isolation
battery set to
"charge".
connector (no contact
Link loose or broken
cal contacts and
Make sure the nuts
are tight (CHECK).
Zero volt with the
battery set to
"discharge".
Battery fully discharged. Charge the battery
(DESCRIPTION AND
OPERATION).
Do an insulation
check (CHECK).
Battery circuit open or
Examine the contacts
defective contacts.
and links. Make sure
the terminal nuts
are tight (CHECK).
Refer to the related
subsequent steps.
Leakage of electro-
Incorrect adjustment of Disassemble and clean
lyte.
the battery
(DISAS-
SEMBLY and CLEANING).
Do an electrolyte
level check (CHECK).
Cell polarity inco-
Examine the aircraft
rrect during high-rate
circuit which charges
discharge (for example,
during the engine start).
24-39-06
Page 101
Apr 01/92
The document reference is online, please check the correspondence between the online documentation and the printed version.