01/20/2015 Sailsh320CCOwner’sManual|sailshboats.com 21
Fishbox Pump
The 320 CC is equipped with a diaphragm pump called the gulper grouper (pictured to
the right). The Whale Gulper Grouper pump has no impeller to clog or burn out. Unlike
impeller pumps these have no-choke valves that easily pump out sh box waste.
They also offer long term durability, they can run dry without causing damage.
Troubleshooting
Electric Motor Runs but doesn’t pump
Disconnect pump and turn off all power.
Disconnect hoses and unscrew housings.
Check entire hose system for blockage.
Inspect tricuspid valves for blockage or inverted valve(s).
If valve(s) are blocked, remove blockage, re-assemble the pump and continue
use.
If a tricuspid valve is inverted, replace with a new tricuspid valve, reassemble
the pump and continue use.
If the electric motor will not operate, check that:
The isolator switch is on.
There is 12 volts at the battery terminals.
The in-line fuse / circuit breaker are operational.
If the fuse / circuit breaker has blown, check for debris in pump head and clean out
if necessary. Replace the fuse or re-set circuit breaker and run the pump.