PDS33 Series
- 38 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
current fault
E0.07
Controller’s
status record of
current fault
E007
E0.08
Time record of
current fault
Calculated
from powering
on
E008
E0.09
Time record of
current fault
Calculated
from starting
E009
Parameter interpretation:
F0.01, Start/Stop Mode Option: If set to 0, start-stop control of keyboard panel, if
set to 1, the external terminal control start-stop, DI1 and COM conduction start,
disconnected to stop;
F2.01-F2.05,Motor parameter: the user can set according to the actual pump motor
nameplate parameters
FE.00 user password: the user can set a 5 digits password; after the password is set
up and confirmed, the password will be valid for a minute.
FD.07, Automatic start when power on: the factory defaults to 0 (disabled). It can
be set to 1 (enabled), then as long as the solar module power supply, the controller
will automatically start and achieve automatic operation of the whole day.
FD.10 water shortage detection time: when applied to a deep well pump, not using
the water level probe to detect the water shortage, the controller can use the
built-in water shortage detection function to complete the water shortage detection.
When this parameter is not 0, the software will start the function of water shortage.
Software shortage detection principle: If the water shortage happens, the controller