PDS33 Series
- 47 -
DO flag
1009H
1
R
AI1 voltage
100AH
0.01V
R
AI2 voltage
100BH
0.01V
R
Set voltage
100CH
0.1V
R
PV input power
100DH
0.01kW
R
PV input current
100EH
0.1A
R
Motor speed
100FH
1rpm
R
Inverter temperature
1010H
1
R
Set frequency
1011H
0.01Hz
R
Max frequency
1012H
0.01Hz
R
Controller’s status
1013H
0001FWD running
0002REV running
0003Stand-by
0004Fault
0005Under voltage
0006Exchanging
between
R
Water level
1014H
0Normal
1Low level of well
2High level of reservoir
R
Light status
1015H
0Normal
1Weak
R
Total power on hour
1016H
1H
R
Total running hour
1017H
1H
R
Inverter energy
1018H
0.01kWh
R
Fault code
101AH
Such as
0002:Err02
0003:Err03
R
Fault code 0
101BH
R
Fault frequency
101CH
0.01Hz
R
Fault current
101DH
0.1A
R
Fault voltage
101EH
0.1V
R
Fault Number
101FH
1
R