Figure 5.14 Connecting cables
3. Feed the positive and negative cables into corresponding lock screws.
4. Insert the positive and negative connectors into positive cable and negative cable
whose insulated enclosure has been stripped off, and crimp them tightly with a wire
crimper. Make sure that the withdrawal force of the pressed cable is bigger than
400N.
5. Plug in the pressed positive and negative cables into relevant insulated enclosure,
a “clicksound should be heard when the contact cable assembly is seated correctly.
6. Fasten the lock screws on positive and negative connectors into respective
insulated enclosure and make them tight.
7. Connect the positive and negative connectors into positive and negative DC input
terminals of the inverter, a “click” sound should be heard when the contact cable
assembly is seated correctly.
1. Connection port
Figure 5.15 Connect the inverter
NOTICE
· Before inserting the connector into DC input terminal of the inverter, please make sure that
the DC switch of the inverter is OFF.
·Please use the original H4 terminal to install.