R5 Series
- 1 -

Questions and Answers

  • T
    tony05Sep 23, 2025
    What to do if SAJ R5-5K-S2 Inverter shows Relay Error?
    • C
      Chad GriffinSep 23, 2025
      If your SAJ Inverter displays a Relay Error frequently, contact your distributor or SAJ technical support for assistance.
  • S
    Stephen LopezAug 25, 2025
    What to do if GFCI Error appears on SAJ R5-5K-S2?
    • D
      David WolfeAug 25, 2025
      To resolve a GFCI Error on your SAJ Inverter: * Check the insulation resistance of both the positive and negative sides of the solar panel. * Ensure the inverter isn't in a wet environment. * Verify the inverter's grounding. If the problem persists, contact your distributor or SAJ technical support.
  • J
    Jasmine CastanedaAug 25, 2025
    How to fix ISO Error on SAJ R5-5K-S2 Inverter?
    • R
      Rebecca WashingtonAug 26, 2025
      To solve the ISO Error on your SAJ Inverter: * Check the insulation resistance on both the positive and negative sides of the solar panel. * Make sure the inverter is not in a wet environment. * Confirm the grounding of the inverter is secure. If the problem continues, contact your distributor or SAJ technical support.
  • H
    Hannah LiuAug 27, 2025
    How to resolve Frequency Error on SAJ Inverter?
    • M
      munozkevinAug 27, 2025
      To address a Frequency Error on your SAJ Inverter, check the country and frequency settings for your local grid. If the problem persists, contact your distributor or SAJ technical support.
  • H
    Hunter JonesAug 27, 2025
    What to do if Overcurrent error occurs on SAJ R5-5K-S2?
    • K
      Kellie Taylor DVMAug 27, 2025
      To solve an Overcurrent issue on your SAJ Inverter: * Check the connection between the inverter and the grid. * Test the grid voltage to ensure it is stable. If the problem persists, contact your distributor or SAJ technical support.
  • E
    Emily KentSep 13, 2025
    What to do if my SAJ R5-5K-S2 has Lost Communication?
    • M
      Michelle PooleSep 14, 2025
      If your SAJ Inverter displays a Lost Communication error, verify the connection of the communication cables between the control board and the display board. If the connection is correct, contact your distributor or SAJ technical support.
  • J
    Jessica SparksSep 12, 2025
    What causes High Temperature Error on SAJ Inverter?
    • M
      Mr. Ian DawsonSep 12, 2025
      If your SAJ Inverter displays a High Temperature Error, check if the radiator is blocked and ensure the inverter is not operating in excessively high or low temperatures. If these conditions are normal, contact your distributor or SAJ technical support.
  • K
    Katherine ShepherdSep 12, 2025
    What does Null line-to-earth voltage fault mean on SAJ Inverter?
    • J
      Jaime PerezSep 12, 2025
      If your SAJ Inverter shows a Null line-to-earth voltage fault, check the stability and reliability of the AC output grounding terminal connection. If it's normal, contact your distributor or SAJ technical support.
  • B
    Blake GeorgeSep 4, 2025
    What to do if my SAJ R5-5K-S2 Inverter shows an AC Voltage Error?
    • R
      Robert YoungSep 4, 2025
      If your SAJ Inverter displays an AC Voltage Error, start by checking the grid voltage and the connection between the inverter and the grid. Also, verify the inverter's on-grid standard settings.
  • P
    Paul FieldsSep 2, 2025
    What to do if DCI Device Error appears on SAJ R5-5K-S2?
    • V
      Veronica GriffinSep 2, 2025
      If you are experiencing a DCI Device Error with your SAJ Inverter frequently, contact your distributor or SAJ technical support for assistance.

Summary

Chapter 1 Safety Precautions

1.2 Safety Instructions

Explains hazard symbols like DANGER, WARNING, CAUTION, NOTICE.

Chapter 2 Preparation

2.1 Safety Instructions

Provides safety guidelines regarding electrical shock, high voltage, and environmental conditions.

Chapter 3 Product Information

3.4 Datasheet

Provides technical specifications for R5-0.7K/1K/1.5K-S1 models.

Chapter 4 Instructions for Installation

4.1 Safety Instructions

Warns about dangers of fire, electricity shock, and installation near inflammable items.

Chapter 5 Electrical Connection

5.1 Safety Instruction for Hot-line Job

Stresses that electrical connection must be done by professional technicians with protective equipment.

5.3 AC Connection

Explains the AC connection procedures for R5 series inverters.

Chapter 6 Debugging Instructions

Chapter 7 Fault Code and Troubleshooting

SAJ Warranty Policy

SAJ R5-5K-S2 Specifications

General IconGeneral
ModelR5-5K-S2
Rated Power5000 W
Start Voltage120 V
Number of MPPTs2
Max. Input Current per MPPT13 A
Max Input Current26 A
Rated AC Voltage230 V
AC Voltage Range180-280V
Rated Frequency50 Hz / 60 Hz
THDI<3%
Power Factor>0.99
Euro Efficiency97.5%
DC SwitchIntegrated
Protection DegreeIP65
Cooling MethodNatural Convection
Max. DC Power6500 W
Operating Temperature Range-25°C to 60°C
CommunicationWiFi
Humidity0~100%